Project Background
Based on the functional layout, large spans were required in the product entry and production areas. Therefore, a precast reinforced concrete structural system was chosen. At the front of the building, there is a section housing administrative offices, where the gallery space, elevator shaft, and stairs are resolved using a steel structural system. Additionally, extra product entry/exit zones and storage areas have also been designed with a steel structural system.
Architectural Construction Drawings - Building Construction
Development of Architecture and Structural System
Combination of Prefabricated Load-Bearing System and Steel Load-Bearing System
Floor Plan
Office Building Ground Floor
Office Building First Floor
Office Building Second Floor
Elevation Plan
West View
East View
South View
Noth View
Section Plan
Section A-A
Section B-B
Architectural Renderings(Drawing/Photo)
West View Real Photo
West View Render
Perspective Render
Architectural Construction Drawings - Structural Construction
Foundation Plan
Column Layout Plan
Slab Plan
Roof Panel Layout Plan
Steel Elevator Shaft and Stair Drawings
Steel Slab Drawings
Seismic Design
The building's seismic classification is determined under the Turkish Building Earthquake Code. Factors such as purpose, soil conditions, earthquake design parameters, structural system, number of floors, and height are considered. Structural calculations are clarified using design software. This facility, classified as a high-importance industrial structure, is designated as Class B.